<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-10 20-05-28
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 45 dBuV VOLTAGE
Pilot RDS Phase Difference
6.4 kHz 4.1 kHz -11 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
5 kHz 70 kHz 7057 68,3151
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
6,7 dBr 7,64 dBr 8,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 20:05, 10.04.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (41 dBuV) Max at: 70 kHz MIN: 5 kHz % above 76 kHz: 68,3151 Acquired: 2025/04/10 20:04:24 Total samples: 7057 Equivalent time: 0:05:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 8,0 dBr MIN: 6,7 dBr AVE: 7,64 dBr % above 10,2 dBr: 0,0 Last value: 7,6 dBr (2025/04/10 20:04:23) Station: 96.90 MHz, signal: 4/5 (42 dBuV) 19:58 19:59 20:00 20:01 20:02 20:03 20:04 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality